CRX
Dynamic
      Receiving unit with 12 analogue outputs and 64 digital outputs via CANopen interface, 4 MOSFET digital outputs. Connecting interfaces with M12 circular connectors, 10-pin reduced plug or cable gland. Internal antenna or external antenna as an option.
    
    
    
    
   
       
       
       
       
       
       
       
       
       
      TECHNICAL DATA SHEET
| Power supply | 8-30 VDC | 
| Antenna | Internal antenna; External optional with 1 or 5 meters extension cord | 
| Max number of outputs | 12 analog 64 digital 4 mosfet digital outputs | 
| Rated current of STOP / Safety outputs | SO_1 = 2 A (30 VDC) SO_2 = 2 A (30 VDC) | 
| Rated current of digital outputs | 2 A (30 VDC) | 
| Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061) | up to PL e, cat. 4 / SIL 3 | 
| Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061) | up to PL d, cat. 3 / SIL 2 | 
| Protection degree | IP65 (NEMA 4) | 
| Operating and storage temperature | operating: (-25 °C) ÷ (+70 °C) / (-13 °F) ÷ (+158 °F) storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F) | 
| Connecting interfaces | Customizable - possible solutions include M12 circular connector, 10-pin reduced plug, M12 connector (8+5pin), cable gland | 
| Dimensions | 144 x 162 x 63 mm | 
| Weight | 650 g | 
 
             
             
             
             
             
             
             
             
             
            