ARS

ARS

Base station with prewired outputs: up to 8 analog (voltage) and 12 analog PWM (6 bi-directional axes), maximum 16 digital, also available via CANopen interface. Cabling with two 30-pin connectors (male). External antenna.

Technical data

Power supply
8-30 VDC
Antenna
External. Antenna extension 1 or 5 meter optional.
Max number of outputs
8 analog (voltage)
12 analog PWM (6 bi-directional axes)
16 digital, also available via CANopen interface
Rated current of STOP / Safety outputs
STP_1 = 7.5 A (30 VDC)
STP_2 = 7.5 A (30 VDC)
SAF = 7.5A (30VDC)
Rated current of proportional outputs
2 A (30 VDC) - PWM
10 mA (28 VDC) - voltage
Rated current of digital outputs
2 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061)
up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061)
up to PL d, cat. 3 / SIL 2
Protection degree
IP 65 (NEMA 4)
Operating and storage temperature
operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling
Two 30-pin plugs
Dimensions
189x184x61 mm
7.44x7.24x2.4 in
Weight
850 g
1.9 lb