CRS

CRS

Base station with prewired outputs: 12 analog and 64 digital available via CANopen interface. Cabling with 30-pin connector (male+female). External antenna.

Technical data

Power supply
8-30 VDC
Antenna
External. Antenna extension 1 or 5 meter
Max number of outputs
12 analog
64 digital (via CANopen)
Rated current of STOP / Safety outputs
STP_1 = 8 A (30 VDC)
STP_2 = 8 A (30 VDC)
SAF_1 = 8 A (30 VDC)
SAF_2 = 3 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061)
up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061)
up to PL d, cat. 3 / SIL 2
Protection degree
IP 65 (NEMA 4)
Operating and storage temperature
operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling
30-pin connector
Dimensions
153x147x55 mm
6.02x5.78x2.17 in
Weight
500 g
1.1 lb